How To Buy

qp-BioT

uniqprobe™ uniform quality SPM probe – Contact or dynamic mode for Biology with Triangular cantilevers

The NANOSENSORS uniqprobe combines the well-known features of the other NANOSENSORS AFM probe series such as high application versatility and compatibility with most commercial SPMs with the additional advantage of a strongly reduced dispersion of force constant and resonance frequency. The unsurpassed uniformity of the mechanical characteristics of the uniqprobe series is particularly important for applications, where a large number of probes with known and near identical force constants or resonance frequencies are needed. The sensors of the uniqprobe series are especially adapted for molecular biology, biophysics and quantitative nano-mechanical studies.
 
The reflex gold coating deposited on the detector side of the cantilever covers only the free end above where the tip is located. Main advantages of the uniqprobe coating are considerably less cantilever bending and reduced drift particularly for measurements in liquid environments.
NANOSENORS qp-BioT AFM probes are designed for contact mode or dynamic mode AFM imaging in air or liquid environment. These probes feature two different triangular cantilevers on one side of the support chip. The uniqprobe BioT type offers an alternative to silicon nitride probes, with the advantage of taller tips with smaller opening angles and reduced drift.
 
The probe offers unique features:
  • small dispersion of force constant and resonance frequency 
  • typical tip height 7µm 
  • typical tip radius of curvature smaller than 10nm
  • stress free cantilevers with considerably less bending
  • tip and cantilevers are made of a quartz-like material
  • reduced drift for applications in liquid environments
  • tip repositioning accuracy of better than ± 8 µm (in combination with Alignment Chip)
  • chemically inert

Cantilever data:

Property Nominal Value Specified Range
Thickness /nm
CB1: 900
CB2: 900
CB1: 870 - 930
CB2: 870 - 930
Mean Width /µm
CB1: 2x14
CB2: 2x28
CB1: 2x13 - 2x15
CB2: 2x27 - 2x29
Length /µm
CB1: 100
CB2: 200
CB1: 95 - 105
CB2: 195 - 205
Force Constant /(N/m)
CB1: 0.3
CB2: 0.08
CB1: 0.15 - 0.45
CB2: 0.06 - 0.12
Resonance Frequency /kHz
CB1: 50
CB2: 20
CB1: 42 - 58
CB2: 16 - 24

Order codes and shipping units:

Order Code Number of AFM probes per pack Data sheet Coating
qp-BioT-10 10 without partial Au coating
qp-BioT-20 20 without partial Au coating
qp-BioT-50 50 without partial Au coating


 

Special handling information for NANOSENSORS™ uniqprobes

Due to their unique geometry the tips of the uniqprobes are more susceptible to tip damage by electrostatic discharge (ESD) than other Silicon-SPM-Probes.

Electric fields near the probe chip may lead to field evaporation which can blunt the tip apex of the probe tip. Therefore the NANOSENSORS™ uniqprobes are shipped in specially designed ESD-safe chip carriers.

NANOSENSORS™ recommends to their customers to take appropriate precautions to avoid tip damage due to electrostatic discharge when handling the probes. This can for example be done by using anti-electrostatic mats, wrist bands and tweezers.

Product screencast NANOSENSORS™ uniqprobe AFM Probes series

Please watch the new Product Screencast on the NANOSENSORS™ uniqprobe AFM Probes series by product developer Dr. Laure Aeschimann at YouTube
Please subscribe to the NANOSENSORS Youtube Channel.


For further information please contact your local distributor or NANOSENSORS™ directly.
NANOSENSORS™ is a trademark of NanoWorld AG / info@nanosensors.com / www.nanosensors.com


NANOSENSORS™ is a trademark of NanoWorld AG - Copyright by NanoWorld AG