{"id":4461,"date":"2021-03-31T09:37:44","date_gmt":"2021-03-31T06:37:44","guid":{"rendered":"https:\/\/nanosensors.com\/blog\/nanosensors-afm-probes-for-magnetic-force-microscopy\/"},"modified":"2023-03-15T14:49:55","modified_gmt":"2023-03-15T12:49:55","slug":"nanosensors-afm-probes-for-magnetic-force-microscopy","status":"publish","type":"post","link":"https:\/\/www.nanosensors.com\/blog\/nanosensors-afm-probes-for-magnetic-force-microscopy\/","title":{"rendered":"NANOSENSORS AFM probes for Magnetic Force Microscopy"},"content":{"rendered":"\n<p>Did you know that NANOSENSORS offers six different types of AFM probes for Magnetic Force Microscopy ( MFM) for scanning and investigating sample surfaces with magnetic features?<\/p>\n\n\n\n<p><a href=\"https:\/\/www.nanosensors.com\/pointprobe-plus-magnetic-force-microscopy-reflex-coating-afm-tip-PPP-MFMR\" target=\"_blank\" rel=\"noreferrer noopener\">PPP-MFMR <\/a>\u2013 AFM tip with hard magnetic coating, sensitivity, resolution and coercivity designed for standard magnetic force microscopy applications<\/p>\n\n\n\n<p><a href=\"https:\/\/www.nanosensors.com\/pointprobe-plus-magnetic-force-microscopy-low-momentum-reflex-coating-afm-tip-PPP-LM-MFMR\" target=\"_blank\" rel=\"noreferrer noopener\">PPP-LM-MFMR <\/a>\u2013 designed for magnetic force microscopy with reduced disturbance of the magnetic sample by the MFM tip and enhanced lateral resolution<\/p>\n\n\n\n<p><a href=\"https:\/\/www.nanosensors.com\/pointprobe-plus-magnetic-force-microscopy-low-coercivity-reflex-coating-afm-tip-PPP-LC-MFMR\" target=\"_blank\" rel=\"noreferrer noopener\">PPP-LC-MFMR<\/a> \u2013 &nbsp;MFM tip with soft magnetic coating designed for the measurement of magnetic domains in soft magnetic samples<\/p>\n\n\n\n<p><a href=\"https:\/\/www.nanosensors.com\/pointprobe-plus-magnetic-force-microscopy-high-quality-factor-low-coercivity-reflex-coating-afm-tip-PPP-QLC-MFMR\" target=\"_blank\" rel=\"noreferrer noopener\">PPP-QLC-MFMR <\/a>\u2013 &nbsp;low coercivity MFM probe designed for high operation stability and low disturbance of magnetic samples under ultrahigh vacuum ( UHV ) conditions<\/p>\n\n\n\n<p><a href=\"https:\/\/www.nanosensors.com\/supersharpsilicon-magnetic-force-microscopy-reflex-coating-afm-tip-SSS-MFMR\" target=\"_blank\" rel=\"noreferrer noopener\">SSS-MFMR <\/a>\u2013 SuperSharp MFM probe for high resolution magnetic force imaging, low magnetic moment for reduced disturbance of soft magnetic samples<\/p>\n\n\n\n<p><a href=\"https:\/\/www.nanosensors.com\/supersharpsilicon-high-quality-factor-magnetic-force-microscopy-reflex-coating-afm-tip-SSS-QMFMR\" target=\"_blank\" rel=\"noreferrer noopener\">SSS-QMFMR<\/a> \u2013 SuperSharp MFM probe for high resolution magnetic force imaging with a high mechanical Q-factor for applications in ultrahigh vacuum ( UHV ) .<\/p>\n\n\n\n<p>The screencast introducing all these different MFM probes, their properties and their applications held by our Head of R&amp;D Thomas Sulzbach has just passed the 1500 views mark. Congratulations Thomas!<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"nv-iframe-embed\"><iframe loading=\"lazy\" title=\"Product Screencast NANOSENSORS\u2122 Magnetic Force Microscopy probes\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/qssFxoZ8ELY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/div>\n<\/div><figcaption>NANOSENSORS AFM tips for Magnetic Force Microscopy<\/figcaption><\/figure>\n\n\n\n<p>For further details please have a look at the <a href=\"https:\/\/www.nanosensors.com\/uploads\/media\/files\/0001\/05\/66c03cd27c61296b994fb46dde1ef6b7e1510ddd.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">NANOSENSORS MFM probes brochure<\/a>.<\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"https:\/\/www.nanosensors.com\/blog\/?s=MFM\" target=\"_blank\">Application examples for NANOSENSORS AFM probes for Magnetic Force Microscopy<\/a> can be found in the NANOSENSORS blog.<\/p>\n\n\n\n<p>NANOSENSORS screencasts on Magnetic Force Microscopy AFM probes are also available in <\/p>\n\n\n\n<p>Chinese<\/p>\n\n\n\n<p> on youku <a href=\"http:\/\/v.youku.com\/v_show\/id_XMTQ2OTE4MzU4OA==.html?from=y1.7-1.2\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/v.youku.com\/v_show\/id_XNzMyMDg2MjQ4.html<\/a><\/p>\n\n\n\n<p>and Youtube<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"nv-iframe-embed\"><iframe loading=\"lazy\" title=\"\u78c1\u529b\u663e\u5fae\u955c\u63a2\u9488 MFM\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/m-466qXbAbA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<p>and <\/p>\n\n\n\n<p>Japanese<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"nv-iframe-embed\"><iframe loading=\"lazy\" title=\"\u78c1\u6c17\u529b\u9855\u5fae\u93e1\u7528 \u78c1\u6027\u819c\u30b3\u30fc\u30c8\u30d7\u30ed\u30fc\u30d6 Magnetic Coating\" width=\"1200\" height=\"675\" src=\"https:\/\/www.youtube.com\/embed\/w8Ch6Lx0RoQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Did you know that NANOSENSORS offers six different types of AFM probes for Magnetic Force Microscopy ( MFM) for scanning and investigating sample surfaces with magnetic features? PPP-MFMR \u2013 AFM tip with hard magnetic coating, sensitivity, resolution and coercivity designed for standard magnetic force microscopy applications PPP-LM-MFMR \u2013 designed for magnetic force microscopy with reduced&hellip;&nbsp;<a href=\"https:\/\/www.nanosensors.com\/blog\/nanosensors-afm-probes-for-magnetic-force-microscopy\/\" class=\"\" rel=\"bookmark\">Read More &raquo;<span class=\"screen-reader-text\">NANOSENSORS AFM probes for Magnetic Force Microscopy<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[8,5],"tags":[531,180,31,95,94,592,591,519,589,514,415,590,229,530,518,532],"class_list":{"0":"post-4461","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"hentry","6":"category-nanosensors-news","7":"category-videos","8":"tag-magnetic-afm-probes","9":"tag-magnetic-force-microscopy","10":"tag-magnetic-force-microscopy-probe","11":"tag-mfm-probes","12":"tag-mfm-tips","13":"tag-mfm","16":"tag-ppp-lc-mfmr","17":"tag-ppp-lm-mfmr","18":"tag-ppp-mfmr","19":"tag-ppp-qlc-mfmr","20":"tag-sss-mfmr","21":"tag-sss-qmfmr","22":"tag-518","23":"tag-532"},"_links":{"self":[{"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/posts\/4461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/comments?post=4461"}],"version-history":[{"count":0,"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/posts\/4461\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/media?parent=4461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/categories?post=4461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.nanosensors.com\/blog\/wp-json\/wp\/v2\/tags?post=4461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}