Non-Contact / Tapping Mode (NC)    Non-Contact / Tapping Mode (NC)
Click on Order code for datasheet.

   AdvancedTEC™
ATEC-NC ATEC-NC
Advanced Tip at the End of the Cantilever™
• real tip visibility from top
Non-Contact
• C = 45 N/m; fo = 335 kHz

   Pointprobe® Series
PPP
PPP-NCH
Pointprobe® Plus - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
PPP-NCHR
Pointprobe® Plus - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
  new! PPP-XYNCHR
XY-auto alignment
  with Alignment Chip
Pointprobe® Plus - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
  PPP-QNCHR
Pointprobe® Plus - tip
• High Quality Factor (30000)
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
PPP-NCL
Pointprobe® Plus - tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
PPP-NCLR
Pointprobe® Plus - tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
• Backside Reflex coating
     
new!PPP-NCST
Pointprobe® Plus - tip
Non-Contact Soft Tapping
•C = 7.4 N/m, fo = 160 kHz
  new!PPP-NCSTR
Pointprobe® Plus - tip
Non-Contact Soft Tapping
• C = 7.4 N/m, fo = 160 kHz
• Backside Reflex coating
     
    new!PPP-XYNCSTR
XY-auto alignment
  with Alignment Chip
Pointprobe® Plus - tip
Non-Contact Soft Tapping
• C = 7.4 N/m, fo = 160 kHz
• Backside Reflex coating
PPP-SEIH
Pointprobe® Plus - tip
• for Seiko Instruments microscope
High frequency
• C = 15 N/m, fo = 130 kHz
PPP-SEIHR
Pointprobe® Plus - tip
• for Seiko Instruments microscope
High frequency
• C = 15 N/m, fo = 130 kHz
• Backside Reflex coating
   
   Rotated Tip
PPP-RT
                                                             PPP-RT-NCHR
Pointprobe® Plus with Rotated Tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
   SuperSharpSilicon™
PPP
SSS-NCH
SuperSharpSilicon - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
SSS-NCHR
SuperSharpSilicon - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
SSS-NCL
SuperSharpSilicon - tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
SSS-NCLR
SuperSharpSilicon - tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
• Backside Reflex coating
SSS-SEIH
SuperSharpSilicon - tip
• for Seiko Instruments microscope
High frequency
• C = 15 N/m, fo = 130 kHz
SSS-SEIHR
SuperSharpSilicon - tip
• for Seiko Instruments microscope
High frequency
• C = 15 N/m, fo = 130 kHz
• Backside Reflex coating
   High Aspect Ratio Tips
AR5
AR5-NCH
• High Aspect Ratio Tip
Aspect Ratio ≥ 5:1
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
AR5-NCHR
• High Aspect Ratio Tip
Aspect Ratio ≥ 5:1
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
AR5-NCL
• High Aspect Ratio Tip
Aspect Ratio ≥ 5:1
Non-Contact LLong cantilever
• C = 48 N/m, fo = 190 kHz
AR5-NCLR
• High Aspect Ratio Tip
Aspect Ratio ≥ 5:1
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
• Backside Reflex coating
AR5T
AR5T-NCH
• High Aspect Ratio Tip
Aspect Ratio ≥ 5:1
Tilt compensation: 13°
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
AR5T-NCHR
• High Aspect Ratio Tip
Aspect Ratio ≥ 5:1
Tilt compensation: 13°
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
AR10
AR10-NCH
• High Aspect Ratio Tip
Aspect Ratio ≥ 10:1
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
AR10-NCHR
• High Aspect Ratio Tip
Aspect Ratio ≥ 10:1
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
AR10T
AR10T-NCH
• High Aspect Ratio Tip
Aspect Ratio ≥ 10:1
Tilt compensation: 13°
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
AR10T-NCHR
• High Aspect Ratio Tip
Aspect Ratio ≥ 10:1
Tilt compensation: 13°
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
   Tipless Cantilevers
TL
TL-NCH
Tipless Cantilever
Non-Contact
High frequency
• C = 42 N/m, fo = 330 kHz
TL-NCL
Tipless Cantilever
Non-Contact
Long cantilever
• C = 48 N/m, fo = 190 kHz
   Plateau Tips
AR5

new!PL2-NCH
PLateau tip – diameter 1.8 µm
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz

new!PL2-NCHR
PLateau tip – diameter 1.8 µm
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating

new!PL2-NCL
PLateau tip – diameter 1.8 µm
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz

new!PL2-NCLR
PLateau tip – diameter 1.8 µm
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
• Backside Reflex coating
   Platinium-Iridium Coated Tips
PPP
PPP-NCHPt
Pointprobe® Plus - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
PtIr5 coated probe
PPP-NCLPt
Pointprobe® Plus - tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
PtIr5 coated probe
 
new!PPP-NCSTPt
Pointprobe® Plus - tip
Non-Contact Soft Tapping
• C = 7.4 N/m, fo = 160 kHz
PtIr5 coated probe
 
   Gold Coated Tips
PPP
new!PPP-NCHAuD
Pointprobe® Plus - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
Au coating on detector side
 
 
new!PPP-NCHAu
Pointprobe® Plus - tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
Au coating (both sides)
 
 
new!PPP-NCLAuD
Pointprobe® Plus - tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
Au coating on Detector side
 
 
new!PPP-NCLAu
Pointprobe® Plus - tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
Au coating (both sides)
 
 
new!PPP-NCSTAuD
Pointprobe® Plus - tip
Non-Contact Soft Tapping
• C = 7.4 N/m, fo = 160 kHz
Au coating on Detector side
 
 
new!PPP-NCSTAu
Pointprobe® Plus - tip
Non-Contact Soft Tapping
• C = 7.4 N/m, fo = 160 kHz
Au coating (both sides)
 


   Diamond Coated Tips
DT/CDT
                                                      DT-NCHR
Diamond coated Tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
                                                      DT-NCLR
Diamond coated Tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
• Backside Reflex coating
DT/CDT
                                                      CDT-NCHR
Conductive Diamond coated Tip
Non-Contact High frequency
• C = 42 N/m, fo = 330 kHz
• Backside Reflex coating
                                                      CDT-NCLR
Conductive Diamond coated Tip
Non-Contact Long cantilever
• C = 48 N/m, fo = 190 kHz
• Backside Reflex coating