NANOSENSORS™

DT-NCLR

Diamond Coated Tip - Non-Contact/Tapping Mode - Long Cantilever - Reflex Coating

NANOSENSORSDT-NCLR AFM probes are designed for non-contact mode or tapping mode AFM (also known as: attractive or dynamic mode). The NCL type is offered as an alternative to NANOSENSORS™ high frequency non-contact probee (NCH). The NCL type cantilever is recommended if the feedback loop of the microscope does not accept high frequencies (400 kHz) or if the detection system needs a minimum cantilever length > 125 µm. Compared to the high frequency non-contact type NCH the maximum scanning speed is slightly reduced. This AFM probe combines high operation stability with outstanding sensitivity and fast scanning ability.

For applications that require hard contact between tip and sample this sensor offers a real diamond tip-side coating. This coating features extremely high wear resistance due to the unsurpassed hardness of diamond. The typical macroscopic tip radius of curvature is between 100 and 200 nm. Nanoroughnesses in the 10 nm regime improve the resolution on flat surfaces.
The probe offers unique features:
- real diamond coating
- high mechanical Q-factor for high sensitivity
- alignment grooves on backside of silicon holder chip
- precise alignment of the cantilever position (within +/- 2 µm) in conjunction with the usage
  of the alignment chip
- compatible with PointProbe® Plus XY-Alignment Series
The DT Diamond coating is an approximately 100 nm thick coating of polycrystalline diamond on the tip-side of the cantilever leading to an unsurpassed hardness of the tip. The raman spectrum of the coating verifies the real diamond coating.
DT-NCLR Front View  DT-NCLR Graphic
The reflex coating is an approximately 30 nm thick aluminum coating on the detector side of the cantilever which enhances the reflectivity of the laser beam by a factor of about 2.5. Furthermore it prevents light from interfering within the cantilever. The virtually stress-free coating is bending the cantilever less than 3.5% of the cantilever length.
Cantilever data:
Technical Data Nominal Value Specified Range
Thickness /µm 7 6.0 - 8.0
Mean Width /µm 38 30 - 45
Length /µm 225 215 - 235
Force Constant /(N/m) 48 21 - 98
Resonance Frequency /kHz 190 146 - 236
Order codes and shipping units:
Order Code Quantity Data Sheet Coating
DT-NCLR-10 10 of all probes diamond and reflex
DT-NCLR-20 20 of all probes diamond and reflex
DT-NCLR-50 50 without diamond and reflex
DT-NCLR-W > 370 of up to 32 probes diamond and reflex
For further information please contact your local distributor or NANOSENSORS™ directly.